Product overview
External expansion modules work with the IP500 V2 control unit: a dedicated TDM cable connects them to the control unit's expansion port and adds analog extension, digital extension or analog trunk ports to the system. Modules can stand freely, and rack mounting requires the IP500 V2 rack kit; each module needs its own power supply unit.
Analog telephone expansion module
Analog ports deliver calling party information while ringing, cannot update it during a call, and do not set it on outgoing calls; a telephone can match it locally but is not controlled by IP Office. The primary purpose of the display is to show incoming call information; if the calling display standard in use supports text (extension name), both name and number are sent.
| Module | Ports | Capabilities |
|---|---|---|
| Analog telephone module, 16 ports | 16 analog extensions with calling line identification | DTMF dialing (no pulse or loop disconnect), switch-hook transfer (no ground flash), message waiting lamp 51V stepped / 81V / 101V / line reversal / Bellcore FSK |
| Analog telephone module, 30 ports | 30 analog extensions with calling line identification | As above |
Any one of the analog extension ports can be configured as an external paging port: it does not work as a normal extension, must be connected to an external amplifier or speaker through an isolation device, and can also serve as a music-on-hold (MOH) source. The port always appears busy and cannot be dialed directly, only reached through the paging feature; it stays silent when not paging and plays an alert tone before the speech path is connected.
Analog trunk expansion module
The ATM16 adds 16 analog trunks to the system, supports both loop start and ground start, and provides two power failure transfer ports on the first two trunks that can connect analog telephones directly so calls can still be made during a mains failure. Basic Edition systems support only one ATM16 module.
Digital extension expansion module
| Module | Ports | Description |
|---|---|---|
| DS16B / DS16B2 | 16 digital extension ports | Can operate in DS or TCM mode, selected according to the telephone series connected |
| DS30B / DS30B2 | 30 digital extension ports | Requires IP Office 10.1, 9.1 SP12 or 10.0 SP5 and later |
Three points to note when expanding
- Ports on a module come in fixed blocks and capacity increases in steps of 16 or 30 ports, so allowing headroom when planning extension numbers costs less than adding modules in stages.
- Extensions that need power failure transfer should be connected to an analog telephone module with power failure ports or to an ATM16; standard digital extension modules do not provide this capability.
- The link between module and host is a dedicated TDM cable, not a standard network cable; install it according to the supplied cable and port labels and keep it separate from the IP network.
Supplementary official documentation (IP Office R12.3)
The following material is compiled from Avaya official overviews and specification documents to supplement version, component relationship and deployment details; refer to the original documents for definitive capacity and compatibility matrices.
- The R12.3 architecture diagram organizes expansion systems into Expansion System (V2) and Expansion System (L).
- External expansion modules are configured centrally in IP Office Manager; the official documentation includes example configuration screens.
- The type and number of expansion modules must be checked against the platform specifications in the documentation.

Document source and download
The official document referenced here is Avaya IP Office Platform Solution Description R12.3 (2026-04); the original PDF can be obtained under Product Literature in this site's Downloads section.